Indian Standard explained
IS 16014 explained:
gabions and mattresses
Coating classes, mesh types, wire diameters, zinc and polymer requirements, panel tests and the Quality Control Order that covers double twisted gabions in India. Written by MM Industries, manufacturing wire mesh in Raipur since 1995.
Manufacturer since 1995 · ISO 9001:2015 certified plant
At a glance
| Current edition | IS 16014:2024 (Second Revision), published October 2024 |
|---|---|
| Replaces | IS 16014:2018. Last date to implement the 2024 edition: 29 April 2025 |
| Quality Control Order | Steel Wires or Strands, Nylon or Wire Ropes and Wire Mesh (Quality Control) Order, 2024 |
| Not covered | Welded mesh gabions, which have their own standard, IS 16013 |
| BIS committee | MED 10, Wire Ropes and Wire Products |
Quick answer
IS 16014:2024 is the Bureau of Indian Standards specification for double twisted hexagonal wire mesh gabions, revet mattresses, rock fall netting, sack gabions and soil reinforcement facing units. It sets two coating classes (zinc or zinc aluminium alloy, and the same with a polymer coating), three mesh types (10 × 12, 8 × 10 and 6 × 8), wire diameters for mesh, selvedge and lacing wire, minimum coating mass, polymer properties and mesh panel strength tests. The 2024 edition replaced IS 16014:2018 from 29 April 2025, and gabions are listed in the 2024 Quality Control Order.
On this page
Scope
What IS 16014 covers
IS 16014 covers civil engineering products made from double twisted hexagonal mesh, where adjacent wires are twisted together in pairs to form a hexagonal opening. The twist locks the mesh, so the panel resists unravelling if a wire is cut. That is why this construction is used for structures that must deform without failing, such as retaining walls, river training works and slope protection.
The full title of the standard is Mechanically Woven, Double-Twisted, Hexagonal Wire Mesh Gabions, Revet Mattresses, Rock Fall Netting and Other Products for Civil Engineering Purposes (Galvanized Steel Wire or Galvanized Steel Wire with Polymer Coating) — Specification. Five products fall within it:
| Product | What it is | Mesh types allowed |
|---|---|---|
| Gabion | A rectangular box of double twisted mesh, divided by diaphragms and filled with stone on site | 10 × 12 or 8 × 10 |
| Revet mattress | A shallow, wide gabion for lining channels, banks and slopes | 6 × 8 |
| Rock fall netting | Mesh in rolls, draped or anchored over rock faces | 10 × 12, 8 × 10 or 6 × 8 |
| Sack gabion | A cylindrical mesh unit, filled and placed where access is difficult | 10 × 12 or 8 × 10 |
| Facing unit | Mesh facing with continuous base reinforcement, for vertical or inclined reinforced soil walls | 10 × 12 or 8 × 10 |
Source: IS 16014:2024, clauses 1, 3 and 8.
The standard also defines a strong face gabion: a unit whose front face, or front and one side, is made with mesh wire of at least 3.4 mm (at least 4 mm outside diameter where polymer coated) for greater abrasion resistance and face strength. Welded mesh gabions are a different product with their own standard, IS 16013.
Latest status
What changed in the 2024 revision
| Date | Event |
|---|---|
| 2012 | First edition of IS 16014 published |
| 2018 | First revision, IS 16014:2018 |
| 3 July 2024 | Steel Wires or Strands, Nylon or Wire Ropes and Wire Mesh (Quality Control) Order, 2024 issued, covering IS 16014 |
| October 2024 | Second revision, IS 16014:2024, published |
| 1 December 2024 | Quality Control Order in force for medium and large manufacturers (1 March 2025 for small, 1 June 2025 for micro enterprises) |
| 29 April 2025 | Last date for implementing IS 16014:2024. The 2018 edition is withdrawn |
The foreword lists four changes in the second revision:
- New tests for the polymer coating, covering abrasion resistance and corrosion spread from a cut end.
- The punch test widened to two methods, one on a pretensioned sample and one on a sample secured to a rigid frame.
- New terms added to the definitions clause.
- The tables for vertical and inclined facing units revised.
Requirements
Coating classes, mesh types and wire
Two coating classes
| Class | Construction | Fasteners |
|---|---|---|
| Class 1 | Mesh woven from zinc or zinc aluminium alloy coated wire; lacing wire and stiffeners coated the same way | Galvanized steel wire rings |
| Class 2 | Class 1 wire with an outer polymer coating such as PVC or PA6, applied after metallic coating | Stainless steel rings |
Annex B of the standard matches each coating to an ISO 9223 corrosivity category from C2 to CX. Source: IS 16014:2024, clauses 4 and 5.
Mesh types
| Mesh type | Nominal opening D | Tolerance |
|---|---|---|
| 10 × 12 | 100 mm | ± 10 percent |
| 8 × 10 | 80 mm | ± 10 percent |
| 6 × 8 | 60 mm | ± 10 percent |
Source: IS 16014:2024, clause 8.12 and Table 9.
Wire diameters for gabions and sack gabions
| Wire | Class 1 (mm) | Class 2, core / outside (mm) |
|---|---|---|
| Mesh wire | 2.70 or 3.00 | 2.70 / 3.70 |
| Selvedge wire | 3.40 or 3.90 | 3.40 / 4.40 |
| Lacing wire | 2.20 | 2.20 / 3.20 |
Applies to 10 × 12 and 8 × 10 mesh. Source: IS 16014:2024, Tables 1 and 3.
Wire diameters for revet mattresses
| Wire | Class 1 (mm) | Class 2, core / outside (mm) |
|---|---|---|
| Mesh wire | 2.20 | 2.20 / 3.20 |
| Selvedge wire | 2.70 | 2.70 / 3.70 |
| Lacing wire | 2.20 | 2.20 / 3.20 |
6 × 8 mesh. Source: IS 16014:2024, Table 2.
- Wire to IS 280, soft, with a tensile strength of 350 to 550 MPa and at least 10 percent elongation on a 200 mm gauge length.
- Diameter tolerances from ± 0.06 mm on 2.20 mm wire to ± 0.10 mm on 3.90 mm wire.
- Fastener rings of 3 mm wire with a minimum tensile strength of 1,550 MPa, spaced at a nominal 100 mm and never more than 150 mm apart.
Durability
Zinc, zinc aluminium and polymer coatings
A gabion is designed to stand for decades in water, soil and weather. The coating, not the wire, sets its service life, so the standard specifies it closely.
Minimum metallic coating mass
| Wire diameter (mm) | Minimum coating (g/m²) | Diameter tolerance (mm) |
|---|---|---|
| 2.00 | 240 | ± 0.05 |
| 2.20 | 240 | ± 0.06 |
| 2.40 | 260 | ± 0.06 |
| 2.70 | 260 | ± 0.07 |
| 3.00 | 270 | ± 0.08 |
| 3.40 | 270 | ± 0.09 |
| 3.90 | 280 | ± 0.10 |
Heavy coated, soft type wire. Source: IS 16014:2024, Table 8.
- Zinc aluminium alloy coating is either 95 percent zinc with 5 percent aluminium, or 90 percent zinc with 10 percent aluminium.
- Alloy coatings are proven in a sulphur dioxide test to ISO 22479: 28 cycles for the 5 percent alloy and 56 cycles for the 10 percent alloy, with no more than 5 percent dark brown rust.
- The coating must not flake, crack or rub off under the fingers.
Polymer coating for Class 2
| Property | Requirement |
|---|---|
| Thickness | Nominal 0.50 mm, minimum 0.40 mm |
| Specific gravity | 1.30 to 1.35 |
| Tensile strength | At least 20.6 MPa |
| Hardness | Shore D 50 to 60 |
| Brittleness temperature | Not higher than −9 °C |
| Salt spray | 3,000 hours without cracks, blisters, splits or colour change |
| UV resistance | Tensile strength and elongation change no more than 25 percent after 2,500 hours |
| Abrasion, high abrasion grade | Average above 300 cycles |
Source: IS 16014:2024, clauses 7.2, 8.2 and 12.7.
Acceptance
Dimensions, tests and certification
Dimensional tolerances
- Length and width of gabions, mattresses, sack gabions and facing units: ± 5 percent of the ordered size, before filling.
- Height: ± 5 percent above 0.3 m, and +10 percent at 0.3 m and below.
- Rock fall netting rolls: length +1 m to 0, width within one mesh opening.
Mesh panel tests
The standard tests the woven mesh, not only the wire. Minimum values are tabulated by mesh type and coating class for tensile strength parallel and perpendicular to the twist, selvedge strength, punch strength and the strength of the connection between panels made with lacing wire or rings. Take the values for your mesh type and class from Table 7 of the standard.
Tensile tests use a sample about 0.8 m wide, at least three in each direction. The punch test loads the mesh through a 350 mm circular ram, on either a pretensioned sample or one secured to a rigid frame.
Marking and documents
- A metal tag on every product with the manufacturer’s name, product type, mesh type, coating class, mesh wire diameter, size and batch number or date.
- An installation manual from the manufacturer, which the standard makes mandatory.
- A certificate of conformance and batch test reports where the order asks for them, with tensile strength, zinc mass and polymer thickness certified by the wire producer.
Quality Control Order
Gabions, mattresses and other products to IS 16014 are listed in the Steel Wires or Strands, Nylon or Wire Ropes and Wire Mesh (Quality Control) Order, 2024, in force from 1 December 2024 for medium and large manufacturers, 1 March 2025 for small and 1 June 2025 for micro enterprises. Goods made for export are exempt.
For buyers
How to specify IS 16014 gabions
The standard lists what the purchaser must state. Use it as the spine of the tender clause.
- Cite IS 16014:2024.
- Product: gabion, revet mattress, sack gabion, rock fall netting or facing unit.
- Mesh type: 10 × 12, 8 × 10 or 6 × 8.
- Coating class, and for Class 1 whether zinc or zinc aluminium alloy, chosen for the site’s corrosivity category.
- Mesh, selvedge and lacing wire diameters, and for Class 2 the core and outside diameters.
- Unit size and number of diaphragms, and whether a strong face is needed.
- Quantity, certificate of conformance and batch test reports.
From the field
Riverbank and coastal works see constant wetting and abrasion from moving bed load. On those sites, the choice between Class 1 and Class 2, and between zinc and zinc aluminium coating, decides the service life more than any other line in the specification.
Our practice
How we handle gabion enquiries
MM Industries manufactures double twisted hexagonal mesh, sold as Shyama Jali, from galvanized wire at our plant in Raipur. For gabions and revet mattresses, we confirm every enquiry against IS 16014 in writing before we quote.
Share your tender clause with our team. We will confirm the mesh type, the mesh, selvedge and lacing wire diameters and the coating class for your order.
Questions
Frequently asked questions
Yes. Gabions and other products to IS 16014 are covered by the Steel Wires or Strands, Nylon or Wire Ropes and Wire Mesh (Quality Control) Order, 2024. The order applied from 1 December 2024 for medium and large units, 1 March 2025 for small and 1 June 2025 for micro enterprises.
IS 16014:2024, the second revision, published in October 2024. The last date for implementing it was 29 April 2025, and the 2018 edition is withdrawn.
For 10 × 12 and 8 × 10 gabions, 2.70 or 3.00 mm for Class 1 zinc coated wire, and 2.70 mm core with 3.70 mm outside diameter for Class 2 polymer coated wire.
Class 1 uses zinc or zinc aluminium alloy coated wire. Class 2 adds an outer polymer coating, such as PVC or PA6, over the metallic coating and uses stainless steel fasteners.
At least 260 g/m² under Table 8 of IS 16014:2024. Selvedge wire of 3.40 mm needs at least 270 g/m².
No. IS 16014 covers double twisted hexagonal mesh products. Welded mesh gabions are covered by IS 16013.
Keep reading
Related standards and tools
Share your gabion specification
Send the product, mesh type, coating class, wire diameters, unit size and quantity, or your tender clause. Our team will confirm what we can supply against IS 16014 before quoting.